Meinberg IMS-CPE-1002 Capture signals 2x Capture Input Signals

Meinberg IMS-CPE-1002 Capture signals

2x Capture Input Signals

Varenr: IMS-CPE-1002
Alt. varenr: 27112

CPE-1002
Time Capture Inputs
CAP 0 In / CAP 1 In:Two time capture inputs called User Capture 0 and 1 are provided at the front panel (CAP 0 and CAP 1) to measure asynchronous time events. A falling TTL slope at one of these inputs lets the microprocessor save the current real time in its capture buffer.
TxD:Serial Time Telegram
Pin assignment:
2: TxD RS232
3: TxD (A) RS422 
4: /TxD (B) RS422
7: TxD (A) RS422 
8: /TxD (B) RS422
A = non-inverting; B = inverting;
Current Consumption:5 V +-5%, 150 mA