Dataq DI-2008 DAQ & Data Logger System 4-8 Isolated Analog Inputs, ±50V, 16-bit

Dataq DI-2008 DAQ & Data Logger System

4-8 Isolated Analog Inputs, ±50V, 16-bit

Varenr: DI-2008

Dataq Model DI-2008
Thermocouple and Voltage DAQ and Data Logger System, 4-8 Isolated Analog Inputs, ±50 V, 16-bit Resolution, 200Hz, 7 D I/O, Free WinDaq Software

DI-2008 Thermocouple DAQ
This data logger features 8 analog input channelsThis data acquisition system is expandable with ChannelStretch allowing you to connect multiple units and synchronize data recording.This data logger features 7 digital ports
This data logger has a USB interface


DI-2008 USB Thermocouple Data Acquisition system with Windaq software. Features 4 or 8 analog input channels programmable as a thermocouple or voltage input, 16-bit measurement resolution, and a full scale range of ±10mV to ±50V for voltage measurements or Thermocouple types J, K, T, B, R, S, E, or N. Includes a DI-2008 instrument, a 6-foot USB cable, a screwdriver for signal connections, an NIST-traceable calibration certificate, and downloadable WinDaq software

Eight analog input channels adapt to a wide range of measurement types and applications. Each channel can be independently programmed for a thermocouple or voltage measurement. Programmed as a voltage channel you can select one of twelve measurement ranges from ±10 mV to ±50 V. A range of ±5 V supports 4-20 mA measurements using typically a 250 O shunt resistor (model R250 sold separately). Programmed as a thermocouple channel you can select from eight thermocouple types: J, K, T, B, R, S, E, or N. Linearization and junction compensation are automatically applied by the DI-2008 for the selected TC type to deliver values scaled in either °C or °F. Rounding out the DI-2008, a built-in 15 V sensor excitation power supply simplifies external wiring and further reduces overall system cost. Finally, all analog measurements benefit from a 16-bit ADC resolution to reveal even the smallest signal variations. Virtually any measurement will experience a difference in ground potential between the instrument, the signal source, and even between signal sources. Known as common mode voltages, they cause noisy measurements in the best case or damage to the instrument in the worst case unless it’s specifically designed to tolerate them like the DI-2008. Each DI-2008 analog input is electrically isolated from other channels and from ground for safe and accurate measurements in the presence of common mode voltages. Channel isolation means that each analog input is free to float to an independent common mode voltage imposed upon it by the signal source up to 120 V rms, and still provide an accurate and noise-free measurement.

The DI-2008 provides 7 digital ports, each configurable as an input or a switch. Input protection is provided to 30 V. Configured as a switch a digital port can be used to control external loads up to 30 V @ 100 mA, and the switch can be controlled asynchronously without interrupting the scanning process. When activated as inputs two ports allow dual functionality to be used as discrete inputs, or one as a counter and the other a rate input. The rate input features a 50 kHz maximum measurement allocated over twelve programmable measure-ment ranges (10 Hz to 50 kHz full scale). The counter input provides 16-bit resolution and a terminal count value of 65,535. The discrete, counter, and rate inputs are members of the same internal scan list used by the analog input channels. This means that all enabled elements are acquired synchronously, which allows meaningful comparisons between analog and digital channels. For example, the rate input mea-suring engine speed allows rpm data to be acquired synchronously with analog data.

  • Includes a DI-2008 instrument, a 6-foot USB cable, a screwdriver for signal connections, an NIST-traceable calibration certificate, and downloadable WinDaq software
  • Four or Eight differential and isolated analog input channels.
  • Seven bi-directional digital input ports, including:
  • Counter input for totalizing applications
  • Rate input for frequency/flow/rpm applications
  • ChannelStretch™ channel expansion to 128 analog and 112 digital channels (synchronization only available with other DI-2008 units - Unlock code required per device - see Accessories)
  • Programmable voltage and thermocouple measurements per channel
  • 10 mV to 50 V programmable range per channel in 12 steps
  • Programmable support for type J, K, T, B, R, S, E, N thermocouples per channel
  • High resolution (16-bit) measurements (use the Resolution Calculator to determine how small a change you can detect)
  • 2000 Hz sample throughput for a single channel and 200 Hz for two or more
  • USB interface
  • Included WinDaq software for ready-to-run measurements
  • Use HMP60 Probe for Temperature and Humidity Measurements
  • Included .NET class
  • Fully documented device protocol supports other operating systems