Orga Marine Light - L410EX-R03 15cd, 230Vac, IP66, 1xM25 (3NM)

Orga Marine Light - L410EX-R03

15cd, 230Vac, IP66, 1xM25 (3NM)

Varenr: 018907

KEY FEATURES

  • Reliable marine navigation light, low cost of ownership and low power consumption
  • Suitable for Zone 1 and Zone 2 areas with gas explosion hazard Designed to work in conjunction with the NCCP concept
  • ‘U’-coded high voltage AC power supply from the NCCP for low cable costs and failure free synchronisation
  • Light intensity complies with IALA requirements, even if the intensity of the lanterns is reduced with 25% (service condition factor, as per IALA E-200 (2008) Part 2, 5.1)
  • Offshore coated, lightweight, corrosion free, seawater, UV and humidity resistant light alloy base
  • Stainless steel mounting facilities to prevent corrosion problems
  • Integrated Ex e connection box
  • State of the art high power LEDs and technology provide superior life and reliability
  • Very low power consumption due to efficient optical design
  • Anti bird spikes (to prevent bird fouling)

STANDARDS/CERTIFICATION

  • Certified to UK Department of Energy and Climate Change; Standard marking schedule for offshore installations – April 2011, chapter 3.2 – Subsidiary lights
  • Certified to US Coast Guard; 33 C.F.R. Part 67 – Aids to Navigation on artificial islands and fixed structures – May 2004, Chapter 67.05-10, 67.30-5
  • Cenelec EN 60079-0, EN 60079-7 and EN 60079-18
  • Sira 12ATEX3060X;
    ATEX Ex ll 2G Ex e mb op is IIC T4
  • IEC 60079-0, IEC 60079-7 and
    IEC 60079-18
  • IECEx SIR 12.0025X;
    Ex e mb op is llC T4 Gb
  • ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-7 and ABNT NBR IEC 60079-18 (optional)
  • Inmetro NCC 13.1774 X (optional)

SYSTEM DESIGN, CONTROL AND MONITORING

  • Control and monitoring via separate control panel (see separate product information sheet)

PERFORMANCE CHARACTERISTICS

  • Flashing red light, Morse code ‘U’ every 15 seconds by the NCCP
  • Effective intensity: 15cd minimum (equals 3NM at ATF=0.74)
  • Horizontal beam coverage: 360°
  • Vertical beam profile: 2.5° FWTM minimum

ELECTRICAL CHARACTERISTICS

  • Operating voltage: 230Vac max.; 400 Hz; ‘U’ coded supply from the NCCP
  • Power consumption: 5W peak; 0.9W average
  • Connection details: max. 4mm²; one M25 cable gland entry
  • Earth connection: internal max. 4mm² and external M5

PHYSICAL CHARACTERISTICS

  • Dimensions (L x W x H):
    447 x 416 x 314 mm
  • Weight: 21kg
  • Design degree of protection: IP66
  • Operating temperature range:
    -40°C to +55°C