Network Time Server (NTP) with integrated receivr /radio clock and 2x IRIG-B outputs.
 
 
NTP time server with ultra-stable integrated oscillator OCXO-HQ
and Intelligent Reference Selection Algorithm (IRSA).
Intelligent switching between available synchronization sources:
GPS, Time Code (e.g. IRIG-B), Pulse Per Second (PPS), 10MHz or
external NTP servers.

2 x LAN interface 10/100 MBit, RJ45 connector
1 x Terminal RS232 interface, 9pin D-Sub male connector
     for initial setup and configuration
1 x USB Service interface
1 x LC-Display (2 x 40 characters) and 8 push buttons
----------------------------------------------------------------------------------------------
Reference Inputs:
1 x Meinberg GPS antenna input, BNC connector, isolated
1 x PPS input, TTL, pulse duration >= 5µs, active high, female BNC connector
1 x 10 MHz input, sine (1.5Vpp - 5Vpp) or TTL, female BNC connector
1 x Time Code modulated input, BNC connector, isolated by transformer
     Insulation voltage 3000 VDC
     Input impedance: 50 Ohm, 600 Ohm, 5 kOhm
     Internally selectable by jumper (default 600 Ohm)
     Input signal : 600mV to 8V (Mark, peak-to-peak)
1 x Time Code unmodulated input, BNC connector, isolated by opto-coupler
     Insulation voltage          : 3750 Vrms
     Internal series resistor : 330 Ohm,
     Max. input current          : 25mA
     Diode forward voltage : 1.0V...1.3V
     selectable Time Code Inputs, modulated / unmodulated (DCLS):
     B122/123 / B002/003
     B126/127 / B006/007
     IEEE1344 (modulated and DCLS)
     AFNOR NFS 87-500 (modulated and DCLS)
----------------------------------------------------------------------------------------------
Signal Outputs:
2 x RS232 interface, independent, 9pin D-Sub female connector,
     with multi data formats timestrings.
1 x PPS, TTL into 50 ohm, pulse duration 200 msec,
     active high, female BNC connector
1 x Standard Frequency 10 MHz, TTL into 50 ohm, female BNC connector
1 x Time Code AM, amplitude modulated sinewave output (e.g. IRIG-B12x) ,
     3Vpp into 50 ohm, via female BNC connector
1 x Time Code DCLS, Pulse-width modulated output (e.g. IRIG-B00x),
     TTL active high, via female BNC connector
     (AM and DCLS Time Code signals are generated in parallel )
     additionally Time Codes available: IEEE1344 und AFNOR NFS 87-500.
1 x Alarm Relay Output, change-over contact, 3pin DFK connector
----------------------------------------------------------------------------------------------
Technical specifications:
Power supply: 100-240V AC (50/60Hz)
Power consumption: max. 30W
19" metal chassis, 1U/84HP - (442mm wide x 43mm high x 288mm deep)
CE compliant
----------------------------------------------------------------------------------------------
Scope of supply:
The system will be delivered inclusive of GPS/Converter
outdoor antenna, mounting kit and 20m coax-cable (RG58).
Please note: Picture of rear view not showing all connections.