DescriptionGREYHOUND Fast Ethernet Media Module
Port type and quantity8 x ports in total ; 2 x FE MM, ST ; 2 x FE MM, ST ; 2 x FE MM, ST ; 2 x FE MM, ST
Network size - length of cable
Multimode fiber (MM) 50/125 µmport 1 and 3: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 5 and 7: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 2 and 4: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 6 and 8: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km;
Multimode fiber (MM) 62.5/125 µmport 1 and 3: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 5 and 7: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 2 and 4: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 6 and 8: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km;
Power requirements
Operating Voltagepower supply via GREYHOUND switch
Power consumption9 W
Power output in BTU (IT)/h31
Ambient conditions
Operating temperature0-+60 °C
Storage/transport temperature-40-+70 °C
Relative humidity (non-condensing)5-95 %
Mechanical construction
Weight520 g
Protection classIP30
Mechanical stability
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)8 kV contact discharge, 15 kV air discharge
EN 61000-4-3 electromagnetic field35 V/m (80-2700 MHz); 1 kHz, 80% AM
EN 61000-4-4 fast transients (burst)4 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth)
EN 61000-4-6 Conducted Immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 mains frequency voltage30 V, 50 Hz continous; 300 V, 50 Hz 1 s
EMC emitted immunity
EN 55022EN 55032 Class A
FCC CFR47 Part 15FCC 47CFR Part 15, Class A
Approvals
Basis StandardCE, FCC, EN61131
Safety of industrial control equipmentEN60950
SubstationIEC61850, IEEE1613
Scope of delivery and accessories
Scope of deliveryDevice, General safety instructions
Teknisk info

Produktinformasjon

Produsent Hirschmann


Support
Varen er på lager.
Varen er bestilt fra leverandør og leveringsdato er bekreftet.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varen må bestilles fra leverandør.
Varen befinner seg på fjernlager.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varene bestilles fra vår leverandørs lager.
Ubekreftet - Ta kontakt med kundesenter for nærmere informasjon.