Hawke CSB656 (M) F-M75 (FM) M75 SS

Exde ("D" 59,0mm "E"66,2mm) w/Compound

Varenr: CSB656-FM75-M75SS
Gland Size
D-M50-M50 (37,1-14,7)
D-M50-M50 (37,1-14,7)
F-M75-M75 (59,0-66,2)
F-M75-M75 (59,0-66,2)
C-M32-1"NPT (21,9-24,7)
C-M32-1"NPT (21,9-24,7)
C-M32-M32 (21,9-24,7)
C-M32-M32 (21,9-24,7)
A-M20 (M-FM) ("D"11,0 "E"12,5)
A-M20 (M-FM) ("D"11,0 "E"12,5)
B-M25 (M-FM) ("D"16,2 "E"18,4)
B-M25 (M-FM) ("D"16,2 "E"18,4)
2NPT-M50 (37,1-14,7)
2NPT-M50 (37,1-14,7)
BeskrivelseTeknisk infoSupport
Beskrivelse

Application

Outdoor or indoor use.
For use with conduit incorporating individual insulated conductors or for particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit 
‘cold flow’  characteristics.
c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area.

Features

Provides a barrier seal between the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable or conduit.
Seals conductors at entry to enclosure via conduit or enables an existing cable gland to be converted to a barrier type cable gland.
The device is fitted with a simple compound filled chamber which permits packing around individual insulated conductors. Assembly of the cable gland compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure. The 
compound chamber  may be separated from the cured compound to ensure that the chamber has been effectively filled. If required, external voids can be repaired.
Provides female running coupler for cable gland or conduit entry.

Materials & Finishes

The CSB 656N cable gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminum. Brass NPT entries are nickel plated as standard.

Technical Data

  1. Exd IIC Gb, Exe IIC Gb, Extb IIIC Db
  2. Certificate No's
    Baseefa06ATEX0058X and IECEx BAS 06.0015X.
  3. Suitable for use in:
    Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
  4. Construction and Test Standards:
    IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
  5. Ingress Protection:
    IP66, IP67 and 
    IP 68  (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
  6. Deluge Protection to:
    DTS01
  7. Operating Temperature Range:
    -60°C to +80°C
  8. Assembly Instruction Sheet:
    AI 375.

 

CABLE GLAND SELECTION TABLE
Size
Ref.
Entry Thread
Size
Inner Sheath / Cores ‘G’
Metric
Hexagon
Dimensions
Male Female
Metric NPT* Metric NPT* Max. Over
Cores
'B'
Max. Inner
Sheath
'E'
Max. No. of
Cores
Across
Flats
Across
Corners
Standard Option Standard Option
A M20 ¾" ½" M20 ¾" ½" 11.0 12.5 15 74 30.0 32.5
B M25 1" ¾" M25 1" ¾" 16.2 18.4 30 65 36.0 39.5
C M32 1¼" 1" M32 1¼" 1" 21.9 24.7 42 80 46.0 50.5
C2 M40 1½" 1¼" M40 1½" 1¼" 26.3 29.7 60 83 55.0 60.6
D M50 2" 1½" M50 2" 1½" 37.1 41.7 80 94 65.0 70.8
E M63 2½" 2" M63 2½" 2" 47.8 53.5 100 97 80.0 88.0
F M75 3" 2½" M75 3" 2½" 59.0 66.2 / 65.3¹ 120 100 95.0 104.0
'T' — All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
¹ Smaller value is applicable when selecting reduced NPT male entry option. Hexagon dimensions as shown may alter.

Teknisk info

Produktinformasjon

Produsent Hawke International


Support
Varen er på lager.
Varen er bestilt fra leverandør og leveringsdato er bekreftet.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varen må bestilles fra leverandør.
Varen befinner seg på fjernlager.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varene bestilles fra vår leverandørs lager.
Ubekreftet - Ta kontakt med kundesenter for nærmere informasjon.